*Will this be code approved?
*Will this be code approved?
*If grid goes down, is the AC input still connected to inverted PV output and thus it suffers from islanding when the grid goes down?
*If grid goes down, is the AC input still connected to inverted PV output and thus it suffers from islanding when the grid goes down?
*How does this system perform load balancing on each 120V output leg? How much imbalance can it tolerate before it shuts down? I would imagine it shuts down when one tries to pull out more than 3kW from one leg. Make sure to wire up in a balanced way.


=Communications=
=Communications=

Revision as of 03:50, 23 September 2022

Sourcing

  • Source $1600 - [1]

Questions

  • Will this be code approved?
  • If grid goes down, is the AC input still connected to inverted PV output and thus it suffers from islanding when the grid goes down?
  • How does this system perform load balancing on each 120V output leg? How much imbalance can it tolerate before it shuts down? I would imagine it shuts down when one tries to pull out more than 3kW from one leg. Make sure to wire up in a balanced way.

Communications

Hi Sungold,

I'm building a home, want to add your hybrid inverter for our 5 kW solar array. But we are not sure if your inverter complies with utility regulations? Is this inverter UL listed? Does this inverter run with solar/grid in parallel so that when there is not enough sun, it uses additional energy from the grid? Or does it just switch to grid? That is - say I need 4 kW, and there is 3000W coming in from my solar panels. Would the extra 1 kW come from the grid with 3 from the solar - or does it switch fully to grid so that 4 kW are coming from the grid? We need an inverter that does not switch to grid, but only tops off necessary power by using the grid.

We would like to get:

https://sungoldpower.com/products/6000w-48v-hybrid-solar-inverter-split-phase-120-240vac

Would this meet our needs? Or do you have other inverters that could work for us?

Thanks, Marcin


sales03@sungoldpower.com <sales03@sungoldpower.com>

support@sungoldpower.com

Hi Marcin,

Thank you for your inquiry.

Sorry that this inverter is not UL listed. But if you do not need to use the grid feedback function, the inverter does not need to be UL listed. For 6000w 48v hybrid inverter, it has two working modes as the picture shown. The inverter can run with solar/grid in parallel. If you need 4kw, and there is 3000W coming in from your solar panels, the extra 1kw will come from the grid.


Or you can consider our 6500w 48v solar inverter, which is UL standard, but its AC input and AC output is 120v. Here is the link and you can have a look. https://sungoldpower.com/products/6500w-48v-solar-charge-inverter-parallel-wifi-monitor

Best Regards Cindy