[[Image:scceb6order.jpg]] | [[Image:scceb6order.jpg]] | ||
*Note- motor is 12 gpm continuous, so must be activated in parallel with other element or flow reduced | |||
*motor is rated for 1800 psi, so pressure reducer must be used | |||
*for 14 gpm - can use small cylinder motion to reduce flow, or just needle valve. | |||
*for 28 gpm must have 3 solenoids going at once for shaker not to blow up | |||
*cushion valve must be used in all cases | |||
*to test cushion valve, observe pressure with pressure valve in manual mode | |||
*next steps - use log splitter 2 stage pump for faster pressing |
Revision as of 21:00, 28 April 2014
- Note- motor is 12 gpm continuous, so must be activated in parallel with other element or flow reduced
- motor is rated for 1800 psi, so pressure reducer must be used
- for 14 gpm - can use small cylinder motion to reduce flow, or just needle valve.
- for 28 gpm must have 3 solenoids going at once for shaker not to blow up
- cushion valve must be used in all cases
- to test cushion valve, observe pressure with pressure valve in manual mode
- next steps - use log splitter 2 stage pump for faster pressing