*Heaters refversed in Cura. If you set the extruder temperature - and notice that the heatbed temperature is rising instead - then the order of the thermistors has been reversed. Move the extruder thermistor to the connector closer to the power plug on the RAMPS board. See Slide 4 of [[D3D_Controller#Wiring]]
*Heaters refversed in Cura. If you set the extruder temperature - and notice that the heatbed temperature is rising instead - then the order of the thermistors has been reversed. Move the extruder thermistor to the connector closer to the power plug on the RAMPS board. See Slide 4 of [[D3D_Controller#Wiring]] or the slide that has the thermistor wire detail.


=Repair=
=Repair=

Revision as of 01:55, 11 January 2018

Safety

Operation

Troubleshooting

  • Heaters refversed in Cura. If you set the extruder temperature - and notice that the heatbed temperature is rising instead - then the order of the thermistors has been reversed. Move the extruder thermistor to the connector closer to the power plug on the RAMPS board. See Slide 4 of D3D_Controller#Wiring or the slide that has the thermistor wire detail.