Revision as of 23:35, 15 January 2018

Safety

Operation

Setting Bed Leveling Probing

  • For D3D 1612 - set the following coordinates:

D3d1612coords.jpg

  • Note that configuration.h in Arduino code does not set bed size, but only the software endstops.
  • Use 3 point probing in OSE Marlin.
  • To modify probing location, go to Arduino IDE->configuration.h ->

D3d1612probingloc.jpg

Troubleshooting

  • Heaters refversed in Cura. If you set the extruder temperature - and notice that the heatbed temperature is rising instead - then the order of the thermistors has been reversed. Move the extruder thermistor to the connector closer to the power plug on the RAMPS board. See Slide 4 of D3D_Controller#Wiring or the slide that has the thermistor wire detail.