Wiring Stepper Motors in Series: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
Line 1: | Line 1: | ||
=About= | |||
If you want to run 4 Z (or Y) motors with RAMPS, it is possible. To do this, you must have a 24V system (so each series motor gets 12V). This allows you to stay within the current limits of the drivers, without having to use larger drivers if you were running all 4 in parallel. | |||
=Picture Makes Sense= | =Picture Makes Sense= | ||
[[Image:seriesstepper.jpg|800px]] | [[Image:seriesstepper.jpg|800px]] |
Revision as of 19:52, 28 April 2020
About
If you want to run 4 Z (or Y) motors with RAMPS, it is possible. To do this, you must have a 24V system (so each series motor gets 12V). This allows you to stay within the current limits of the drivers, without having to use larger drivers if you were running all 4 in parallel.
Picture Makes Sense
Picture Does not Match Diagram
From [3]. Note the wiring picture above does not match the schematic in the link.
Ultimate Test
Wire as in picture. That should work.