*'''Puncture Resistance''' - RPE is 3x more resistant than EPDM - [https://www.google.com/search?sxsrf=ALeKk026QG9BbsZl0rNsBS9KmerMgczY_w%3A1602863734253&source=hp&ei=dsKJX6q8DJDYsAXHkpG4Cw&q=is+EPDM+more+puncture+proof+than+same+thickness+of+polyethylene&btnK=Google+Search&oq=how+to+configure+nvidia+geforce+gtx+1650+super+on+linux+mint&gs_lcp=CgZwc3ktYWIQAzIFCCEQoAEyBQghEKsCMgUIIRCrAjoOCAAQ6gIQtAIQmgEQ5QI6DgguELEDEMcBEKMCEJMCOggILhDHARCvAToLCC4QsQMQxwEQowI6CAgAELEDEIMBOggILhCxAxCDAToFCAAQsQM6AggAOgQIABAKOgYIABAWEB46CAghEBYQHRAeOgcIIRAKEKABUMsQWOmzAWD8tAFoBnAAeACAAeQGiAGhS5IBDTExLjQ3LjMuMi42LTGYAQCgAQGqAQdnd3Mtd2l6sAEG&sclient=psy-ab&ved=0ahUKEwiqz4DcvLnsAhUQLKwKHUdJBLcQ4dUDCAk&uact=5] | *'''Puncture Resistance''' - RPE is 3x more resistant than EPDM - [https://www.google.com/search?sxsrf=ALeKk026QG9BbsZl0rNsBS9KmerMgczY_w%3A1602863734253&source=hp&ei=dsKJX6q8DJDYsAXHkpG4Cw&q=is+EPDM+more+puncture+proof+than+same+thickness+of+polyethylene&btnK=Google+Search&oq=how+to+configure+nvidia+geforce+gtx+1650+super+on+linux+mint&gs_lcp=CgZwc3ktYWIQAzIFCCEQoAEyBQghEKsCMgUIIRCrAjoOCAAQ6gIQtAIQmgEQ5QI6DgguELEDEMcBEKMCEJMCOggILhDHARCvAToLCC4QsQMQxwEQowI6CAgAELEDEIMBOggILhCxAxCDAToFCAAQsQM6AggAOgQIABAKOgYIABAWEB46CAghEBYQHRAeOgcIIRAKEKABUMsQWOmzAWD8tAFoBnAAeACAAeQGiAGhS5IBDTExLjQ3LjMuMi42LTGYAQCgAQGqAQdnd3Mtd2l6sAEG&sclient=psy-ab&ved=0ahUKEwiqz4DcvLnsAhUQLKwKHUdJBLcQ4dUDCAk&uact=5] | ||
**This video says you need an underlayment with EPDM, but not with RPE. [https://www.youtube.com/watch?v=FkLSFG5tohE]. EPDM folds better around corners. Vid says 1/2 the weight and 3x the puncture resistance - making it a great choice [https://youtu.be/FkLSFG5tohE?t=139] | |||
=SBS= | =SBS= |
Revision as of 18:24, 9 January 2023
About
- Puncture Resistance - RPE is 3x more resistant than EPDM - [1]
SBS
- SBS peel and stick - [4]. 3 ply. 10,000 sf in 160 hours, or 500 sf in 8 hours. Buy at Menards - [5]. 120 mil thick. 3 layers? Or can we do 1 layer + ballast? More info from another manufacturer - [6]
- Note - if it is multiple ply (2 or 3) - it is effectively like doing 2-3 roofs instead of one with EPDM. Proper termination detail still needs to be done at fascia and Bargeboard
- SBS Installation Video
EPDM
- Seam tape - $1/ft [7]
- Seam kit - $3/ft [8]
- Exterior seaming kit - $6/ft [9]
- EPDM - $1.2/sf [10]
- Seam primer [11]
Landfill Liner
- See Landfill Liner
Outdoor Carpet