Line 11: | Line 11: | ||
##Mirror attachment strategy ($1 per slat) | ##Mirror attachment strategy ($1 per slat) | ||
##Conrol electronics, motor, feedback sensor, and control logic ($5 per slat) | ##Conrol electronics, motor, feedback sensor, and control logic ($5 per slat) | ||
#Develop an explicit design for the collector tube ($500) | #Develop an explicit design for the collector tube ($500) | ||
##Source materials | ##Source materials | ||
#Develop valving system for collector tube feedwater entry ($150) | #Develop valving system for collector tube feedwater entry ($150) | ||
#Develop digital fabriction of steam engine ($100) | #Develop digital fabriction of steam engine ($100) | ||
#Modernize said steam engine with electronic steam injection ($50 for valve and controls) | #Modernize said steam engine with electronic steam injection ($50 for valve and controls) | ||
#Develop a matchins electrical generator ($150) | #Develop a matchins electrical generator ($150) | ||
#Integrate additional steam cycle components - cooling, pumping, preheating, superheating ($150) | #Integrate additional steam cycle components - cooling, pumping, preheating, superheating ($150) | ||
Revision as of 18:44, 2 February 2009
Introduction
This page is dedicated to organizing all the aspects of the preparation for Open Solar 2 - OS2 - The Second Solar Power Generator Convergence at Factor e Farm.
The main points are to refine the design of the system and prepare all the materials for integration.
The points to develop prior to OS2 are:
- Demonstrate a working reflector slat. This includes (including cost milestones for materials):
- Structure for holding mirrors ($6 per slat, without mirrors)
- Mirror attachment strategy ($1 per slat)
- Conrol electronics, motor, feedback sensor, and control logic ($5 per slat)
- Develop an explicit design for the collector tube ($500)
- Source materials
- Develop valving system for collector tube feedwater entry ($150)
- Develop digital fabriction of steam engine ($100)
- Modernize said steam engine with electronic steam injection ($50 for valve and controls)
- Develop a matchins electrical generator ($150)
- Integrate additional steam cycle components - cooling, pumping, preheating, superheating ($150)
See OS2 Development Points for details.