Surplus Center CEB 6 Partial Order
Jump to navigation
Jump to search
- Note- motor is 12 gpm continuous, so must be activated in parallel with other element or flow reduced
- Advanced flow reduction strategy - running other components in parallel
- specific speeds and flows must be calibrated
- motor is rated for 1800 psi, so pressure reducer must be used
- for 14 gpm - can use small cylinder motion to reduce flow, or just needle valve.
- for 28 gpm must have 3 solenoids going at once for shaker not to blow up
- cushion valve must be used in all cases
- p spike upon startup is an issue - needs to be tested - data collection - ie - pressure spike upon startup
- to test cushion valve, observe pressure with pressure valve in manual mode
- next steps - use log splitter 2 stage pump for faster pressing