<source src="https://github.com/CabbageBreath/CabbageBreath.github.io/raw/master/Soil%20Mixer%202019/Series%20Circuit%201-1.webm" type="video/webm"> | <source src="https://github.com/CabbageBreath/CabbageBreath.github.io/raw/master/Soil%20Mixer%202019/Series%20Circuit%201-1.webm" type="video/webm"> | ||
</video> | |||
</html> | |||
The next video shows flow (q) and pressure (p) during the simulation. | |||
<html> | |||
</video> | </video> | ||
<video width=" | <video width="50%" height="50%" loop controls mute> | ||
Revision as of 22:24, 18 December 2019
This page includes information about the entire electromechanical hydraulic control system for the soil mixer. This is a variant of CEB Press Controller v19.01
Controller Requirements
- Needs to switch a double acting cylinder while running a hydraulic motor
- Needs to cycle a dc motor for cement dosing
- Water mister solenoid
Hydraulics
Hydraulic Diagram
Hydraulic Circuit Simulation
Series Circuit with motor flow controller
Simulated in Festo FluidSIM
The next video shows flow (q) and pressure (p) during the simulation.