Soil Mixer 2019/Controller: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
Line 42: | Line 42: | ||
</html> | </html> | ||
==Sequence Valve Circuit 1== | ===Sequence Valve Circuit 1=== | ||
Using a pressure relief valve in the simulator as a sequence valve. | Using a pressure relief valve in the simulator as a sequence valve. | ||
Line 56: | Line 56: | ||
</html> | </html> | ||
==Sequence Valve Circuit | ===Sequence Valve Circuit 2=== | ||
Same as above but outlet from cylinder valve is plumbed through a check valve to motor. Increases motor flow during retraction of cylinder. Interesting effect- I didn't expect it. | Same as above but outlet from cylinder valve is plumbed through a check valve to motor. Increases motor flow during retraction of cylinder. Interesting effect- I didn't expect it. | ||
Revision as of 23:45, 18 December 2019
This page includes information about the entire electromechanical hydraulic control system for the soil mixer. This is a variant of CEB Press Controller v19.01
Controller Requirements
- Needs to switch a double acting cylinder while running a hydraulic motor
- Needs to cycle a dc motor for cement dosing
- Water mister solenoid
Hydraulics
Hydraulic Diagram
Hydraulic Circuit Simulation
Series Circuit with three way flow controller on motor
Simulated in Festo FluidSIM 30 minute demo
The next video shows flow (q) and pressure (p) during the simulation.
Sequence Valve Circuit 1
Using a pressure relief valve in the simulator as a sequence valve.
Sequence Valve Circuit 2
Same as above but outlet from cylinder valve is plumbed through a check valve to motor. Increases motor flow during retraction of cylinder. Interesting effect- I didn't expect it.
In both the above videos the setting of the two pressure relief valves changes motor speed and cylinder travel speed. I try to set it to minimize flow through main bypass valve.