10kW Induction Heater: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
=Why 10kW?= | |||
*It is a useful size in a transition from home economics to industrial power. Homes can have 10kW power outlets as a standard option (50a at 240V) | |||
*For industriall power, larger power levels can be built by: multiplying wire connections, scaling the power stage, and using the same control circuit. | |||
=Intro - 10 kW Home Power Circuit= | =Intro - 10 kW Home Power Circuit= | ||
Great study, guy became active again in 2021 from initial work in 2010. | Great study, guy became active again in 2021 from initial work in 2010 - Tutorial at http://inductionheatertutorial.com/ | ||
*Note - someone capable of documenting and adding some calculations and data like this is worth learning from. This is the best tutorial on induction power I've seen so far - this circuitry can be scaled likely to 100kW without much change in topology, using [[Extensive Scalability]] of components. | |||
*YouTube Playlist on components - [https://www.youtube.com/playlist?list=PLK_Je1TKuxtbtrYb9hET-nULzFN_jNbUE] | *YouTube Playlist on components - [https://www.youtube.com/playlist?list=PLK_Je1TKuxtbtrYb9hET-nULzFN_jNbUE] | ||
**Phase lock explained - [https://www.youtube.com/watch?v=5yzPxN2qiAQ&list=PLK_Je1TKuxtbtrYb9hET-nULzFN_jNbUE&index=8&t=191s] | **Phase lock explained - [https://www.youtube.com/watch?v=5yzPxN2qiAQ&list=PLK_Je1TKuxtbtrYb9hET-nULzFN_jNbUE&index=8&t=191s] | ||
**Tank and transformer considerations - [https://www.youtube.com/watch?v=3YpLtqzREEM&list=PLK_Je1TKuxtbtrYb9hET-nULzFN_jNbUE&index=3] | **Tank and transformer considerations - [https://www.youtube.com/watch?v=3YpLtqzREEM&list=PLK_Je1TKuxtbtrYb9hET-nULzFN_jNbUE&index=3] | ||
**How to not blow out mosfets at higher voltage up to 700VDC - [https://www.youtube.com/watch?v=Cum_HAd07Kk&list=PLK_Je1TKuxtbtrYb9hET-nULzFN_jNbUE&index=6] |
Latest revision as of 17:58, 4 June 2022
Why 10kW?
- It is a useful size in a transition from home economics to industrial power. Homes can have 10kW power outlets as a standard option (50a at 240V)
- For industriall power, larger power levels can be built by: multiplying wire connections, scaling the power stage, and using the same control circuit.
Intro - 10 kW Home Power Circuit
Great study, guy became active again in 2021 from initial work in 2010 - Tutorial at http://inductionheatertutorial.com/
- Note - someone capable of documenting and adding some calculations and data like this is worth learning from. This is the best tutorial on induction power I've seen so far - this circuitry can be scaled likely to 100kW without much change in topology, using Extensive Scalability of components.