A simple boiler implementation involves a [[Babington_Burner]] heating the inside of a 6 inch metal pipe of 1/8" wall thickness. A 100 foot long coil of 1/2 inch steel tubing is placed inside this coil, and an electronically-controlled [[Valve delivery system]] (note: in steam engine case, the 'solar boiler' in last link is replaced by the above 100-foot coil of steel tubing.
A simple boiler implementation involves a [[Babington_Burner]] heating the inside of a 6 inch metal pipe of 1/8" wall thickness. A 100 foot long coil of 1/2 inch steel tubing is placed inside this coil, and an electronically-controlled [[Valve delivery system]] (note: in steam engine case, the 'solar boiler' in last link is replaced by the above 100-foot coil of steel tubing.
=Design Rationale=
*Easy to fabricate
*Welds around each tube - 48 welds
**Tubes stick through end plate for welding
*End plates covers are welded on afterwards
*40 square foot area, sufficient for 8 hp steam engine?
[[Image:Boiler.jpg]]
=Review=
By VK Desai of Tinytechindia.com:
Not perfect idea. Flue gas path not shown. Boiler cover not shown. 40 sq feet enough for 4 hp steam engine.


===Materials===
===Materials===
Line 14: Line 29:


Stationary applications can probably get by with a simple style grate biomass boiler. http://www.biomasscombustion.com/horizontal_grate_technology.htm
Stationary applications can probably get by with a simple style grate biomass boiler. http://www.biomasscombustion.com/horizontal_grate_technology.htm




Line 23: Line 39:
**Dremel tool - $40
**Dremel tool - $40
**Dremel micro drill press - $40
**Dremel micro drill press - $40
[[Category:Steam Engine]]
[[Category:Steam Generator]]

Latest revision as of 18:49, 2 May 2011

Main > Energy > Steam Engine


Boiler

A simple boiler implementation involves a Babington_Burner heating the inside of a 6 inch metal pipe of 1/8" wall thickness. A 100 foot long coil of 1/2 inch steel tubing is placed inside this coil, and an electronically-controlled Valve delivery system (note: in steam engine case, the 'solar boiler' in last link is replaced by the above 100-foot coil of steel tubing.

Design Rationale

  • Easy to fabricate
  • Welds around each tube - 48 welds
    • Tubes stick through end plate for welding
  • End plates covers are welded on afterwards
  • 40 square foot area, sufficient for 8 hp steam engine?

Boiler.jpg

Review

By VK Desai of Tinytechindia.com:

Not perfect idea. Flue gas path not shown. Boiler cover not shown. 40 sq feet enough for 4 hp steam engine.

Materials


Boiler Fuel: For transportation vehicles some biomass fuel energy densification is required. Pyrolisis fuels without elaborate processing look promising here is a brief summary of some methods http://www.ars.usda.gov/sp2UserFiles/Program/307/biomasstoDiesel/RobertBrown&JenniferHolmgrenpresentationslides.pdf http://www.biomasscombustion.com/horizontal_grate_technology.htm

Stationary applications can probably get by with a simple style grate biomass boiler. http://www.biomasscombustion.com/horizontal_grate_technology.htm


Flash Steam Generator

    • Coil bending jig - $400
    • Stainless steel coil, 150 feet - $200
    • Babington fittings and metal - $100
    • Dremel tool - $40
    • Dremel micro drill press - $40