Power Cube/User's Manual
Power Cube | ||
---|---|---|
Home | Research & Development | Bill of Materials | Manufacturing Instructions | User's Manual | User Reviews |
Contents
Specifications
- Size
- 26" sq.
- 26.4 L gasoline tank
- 26.4 L hydraulic oil tank
- Weight
- 84lbs -motor
- 9 lbs - pump
- total dry
- total wet
- 28HP motor
- Pump Flow
- 14.4 GPM at 3600 RPM (Max?)
http://bsintek.basco.com/BriggsDocumentDisplay/jkposNDvrS8lFix2.pdf
https://www.surpluscenter.com/item.asp?catname=&qty=1&item=9-1788-B
User Guide
- This section is intended for the end user of the Power Cube.
- 1. Caution
- a) Weight
- b) Hydraulic hazards
- c) Ventilation
- 2. Mounting
- a) Quick attach connector
- 3. Initial startup and testing
- a) Initial Setup
- Gasoline
- Hydraulic Fluid
- Battery Connection
- b) Startup
- c) Hydraulic Test
- a) Initial Setup
- 4. Routine use
- 5. Maintenance
- a) Check fluids
- b) ? ? ?
- 6. Troubleshooting
- a) Engine won't start
- b) Loud noise
- c) No hydraulic power
Troubleshooting
Milky Hydraulic Fluid
Milky hydraulic fluid indicates that there is water in the fluid which should be cleaned out. Some steps that can be taken:
1) flush all hydraulic fluid and replace with new fluid 2) add a water filter or desiccator to the hydraulic system
Cause
1) Condensation on the inside of the hydraulic tank
Solenoid stuck
Possible problems:
1) broken solenoid - measuring the ohms across the solenoid terminals should be between 0 and a few hundred ohms. Any more indicates a blown coil in the solenoid. 2) silt lock - particulates have jammed one of the solenoids or cylinders. 3) physical jam - something is blocking the movement of the cylinder. In the case if the secondary cylinder, it could be something that got stuck in the chamber. The chamber could be bent causing the primary cylinder foot to get jammed.