{{  | {{GVCS Header}}  | ||
=Overview=  | =Overview=  | ||
| Line 7: | Line 7: | ||
=Research=  | =Research=  | ||
===Design Notes===  | |||
'''Maximum Temperature'''  | |||
*Design should keep fluid temperatures below 82 C (180 F). Higher temperatures damage seals, and exceed fluid viscosity limits, damaging components.  | |||
'''Hydraulic Oil Cooler'''  | |||
*Design of hydraulic cooler should be able to dissipate 30% of system heat  | |||
=See Also=  | =See Also=  | ||
*[[Hydraulic Power]] - Calculations  | |||
*[[LifeTrac_hydraulics_primer]]  | |||
=Links=  | |||
*Hydraulic motor in FreeCAD - [https://www.youtube.com/watch?v=73MhBjH2cmY&feature=youtu.be]  | |||
*[http://en.wikipedia.org/wiki/Hydraulic_motor Wikipedia: Hydraulic Motor]  | *[http://en.wikipedia.org/wiki/Hydraulic_motor Wikipedia: Hydraulic Motor]  | ||
*[http://en.wikipedia.org/wiki/Hydraulic_machinery Wikipedia: Hydraulic Machinery]  | *[http://en.wikipedia.org/wiki/Hydraulic_machinery Wikipedia: Hydraulic Machinery]  | ||
*[http://www.delugeinc.com/products.aspx Piston Hydraulic Heat Engine]  | *[http://www.delugeinc.com/products.aspx Piston Hydraulic Heat Engine]  | ||
*[http://www.machinerylubrication.com/article_detail.asp?articleid=659#at Hydraulic Efficiency]  | |||
*[http://www.hydrosafe.com/ Canola Oil Hydraulic Fluid]  | *[http://www.hydrosafe.com/ Canola Oil Hydraulic Fluid]  | ||
{{  | {{GVCS Footer}}  | ||
Latest revision as of 06:34, 24 April 2015
| Hydraulic Motor | ||
|---|---|---|
| Home | Research & Development | Bill of Materials | Manufacturing Instructions | User's Manual | User Reviews | ||
Overview
As the Hydraulic Motor forms a backbone powering many GVCS technologies, local fabrication of the technology enables a number of opportunities.
Research
Design Notes
Maximum Temperature
- Design should keep fluid temperatures below 82 C (180 F). Higher temperatures damage seals, and exceed fluid viscosity limits, damaging components.
 
Hydraulic Oil Cooler
- Design of hydraulic cooler should be able to dissipate 30% of system heat
 
See Also
- Hydraulic Power - Calculations
 - LifeTrac_hydraulics_primer
 
Links
- Hydraulic motor in FreeCAD - [1]
 - Wikipedia: Hydraulic Motor
 - Wikipedia: Hydraulic Machinery
 - Piston Hydraulic Heat Engine
 - Hydraulic Efficiency
 - Canola Oil Hydraulic Fluid